Scotts accugreen 1000 manual pdf. [PDF] Scotts accugreen 1000 drop spreader setting guide 2019-03-03

Scotts accugreen 1000 manual pdf Rating: 5,9/10 1694 reviews

Scotts ACCUGREEN 1000 User Manual

scotts accugreen 1000 manual pdf

With the micrometer set at 6 and the trigger squeezed against the handle, the front edge of the projecting ridge on the shut-off bar should be aligned with the calibration line located on the 2nd or 3rd tooth from the center. Regretfully, it can be quite daunting to find the book that you are looking for because the majority of websites do a poor job of organizing their content or their databases are very small. Again, thank you for taking the time to contact us and for your interest in Scotts. Register a Free 1 month Trial Account. However, if you do find a link that is broken, do not fret. Walking speed is the biggest factor in spreading rates. The owner emailed right back, telling me to use the highest setting because these products have large particles.

Next

What setting do I use on the Scott's Accugreen 1000 drop

scotts accugreen 1000 manual pdf

Turn the micrometer until that number appears in the micrometer window. The owner emailed right back, telling me to use the highest setting because these products have large particles. Why should you choose our website to download Scotts Accugreen 1000 Drop Spreader Setting Guide pdf? Tighten handle assembly and all other nuts. Micrometer W ire Screw micr omet er bar rel 3 into the micr omet er housing 2. Do not completely tighten nuts until the spreader assembly is complete. To adjust the alignment, use a small wrench to turn the black calibration screw at the lower end of the control wire leading from the micrometer insect.

Next

[PDF] Scotts accugreen 1000 drop spreader setting guide

scotts accugreen 1000 manual pdf

Calibration screw Calibration line Shutof f bar W ith y our f oot on the control le v e r, the front edge of the shutof f bar at bot tom of hopper should line up with the calibration line engra v ed into the bot tom of the hopper. F asten legs in place with thumbnuts 6 on outside of hopper. T he Scotts Dif fe rence ® Instr uctions for Assembly and Use 1 Questions, Comments, Inf or mation Scot ts No-Quibble Guar ant ee ® If for any reason you, the consumer, are not satisfied af ter using this product, y ou are entitled to get y our mone y bac k. Pour leftover material bac k into the pac kage and seal pac kage tightly. You may check the calibration of your Scotts Accugreen 3000 by first adjusting your micrometer setting to 6.

Next

Reading : Scotts Accugreen 1000 Manual Pdf

scotts accugreen 1000 manual pdf

Use your foot to squeeze the trigger against the handle. Set Micrometer Turn micro meter until 6 is centere d in window. Adjust the micrometer setting to a 6. One of our associates would be happy to assist you further. Apply Start walking, then squeez e and hold trigger to release product. However, a spreader's calibration may change or slip over time or during periods of heavy use.

Next

Parts list, Frame l egs, Handle

scotts accugreen 1000 manual pdf

Spr eader Maint enance Application Tips F or r ectangular la wns , apply t w o header strips at eac h end of the la wn and then go bac k and f orth. If calibrating the spreader does not help please call us at 800-543-8873 for more assistance. Slide axle w ashers 9 onto axle. . To Calibrate the Accugreen 1000: 1. Please feel free to call us at 1 800 5438873 anytime we may be of assistance. At ta ch legs to hopper , inserting bolts 4 through hopper then leg.

Next

What setting do I use on the Scott's Accugreen 1000 drop

scotts accugreen 1000 manual pdf

Lubricate axle bearings with light oil. The front edge of the shutoff bar should be aligned with the calibration line engraved on the bottom of the hopper. Wheels Slide wheels 8 onto axle with the hub facing out. Ar row Wheel trac ks from previous row Call the toll-free Scotts Consumer Helpline: 1. Chec k Shutof f Ba r Ad just Calibration Scre w If the shutof f bar co v ers the calibration line, tu rn the adjustment scre w counter -cloc kwise.

Next

Reading : Scotts Accugreen 1000 Manual Pdf

scotts accugreen 1000 manual pdf

Who would have thought that downloading an ebook, handbook or a manual would be so easy? The problem is that once you have gotten your nifty new product, the scotts accugreen 1000 drop spreader setting guide gets a brief glance, maybe a once over, but it often tends to get discarded or lost with the original packaging. Anyway, they are organic products, and an overdose will not burn my grass. If you have any difficulty checking or adjusting the calibration, contact us and we will be happy to help walk you through the adjustment. Scotts Accugreen 1000 Manual Pdf can be very useful guide, and scotts accugreen 1000 manual pdf play an important role in your products. The Scot ts Compan y 14 111 Scot tsla wn Rd.

Next

SCOTTS ACCUGREEN 3000 MANUAL Pdf Download.

scotts accugreen 1000 manual pdf

T he Scot ts Compan y w as first to mark et a spreader f or home la wns, bac k in 1 946. Some of the older AccuGreen 3000 Drop Spreader spreader models do not have a raised ridge. W orld rights reser v ed. Turn the spreader over so that you are looking at the outside of the bottom of the hopper. Handle A ssembly Micrometer Housing Micrometer B a rrel B olt, 4 ea. Use your foot to hold down the trigger if your trigger has a locking mechanism you can lock it in place prior to turning upside down.

Next